There was an error with your search parameters. Please clear your search and try again.
1 to 10 of 28 Results
Jun 19, 2020 -
Dendrochronology of 661 Quercus robur for SPONFOREST Project
text/plain - 1.5 MB - MD5: 2b5be08bb6bae15ef3bcd074152f23f9
14 variables in columns and 21 461 tree rings of Quercus robur
1. Patch : a letter is the name of each of the 15 forest stands
2. Tree : tree name. Example : K_001_A means K = stand, 001 = tree number in this stand, A = name of the cored stem when a tree was multi-stemmed
3. Y... |
Jun 19, 2020 -
Dendrochronology of 661 Quercus robur for SPONFOREST Project
text/plain - 22.6 KB - MD5: 90db19fe4e1b3fc9cf53ee1851acdb0e
8 variables in columns and 661 lines for cored pedunculate oaks
1. Patch : a letter is the name of each of the 15 forest stands
2. Tree : tree name. Example : K_001_A means K = stand, 001 = tree number in this stand, A = name of the cored stem when a tree was multi-stemmed
3.... |
Jun 25, 2020 -
Spectra transfer models of near infrared spectra of organic waste and plant samples acquired on different spectrometers
application/octet-stream - 454.8 KB - MD5: c58807592a3574c2674f94b2f85debd2
ThermoScientific ANTARIS II spectrometer gave absorbance spectra in wave numbers with a range of 4000 to 10001 cm-1 and a resolution of 3.86 cm-1. Samples were divided into 10 subsamples (aliquots) and poured into 0.8 cm diameter vials (about 2ml) which was scanned once. For each... |
Jun 25, 2020 -
Spectra transfer models of near infrared spectra of organic waste and plant samples acquired on different spectrometers
application/octet-stream - 927.7 KB - MD5: c3a6c3045073c9ef06b8402f0b255e88
ThermoScientific ANTARIS II spectrometer gave absorbance spectra in wave numbers with a range of 4000 to 10001 cm-1 and a resolution of 3.86 cm-1. Samples were divided into 10 subsamples (aliquots) and poured into 0.8 cm diameter vials (about 2ml) which was scanned once. For each... |
Jun 23, 2020 -
Near infrared spectra of organic waste and plant samples acquired on different spectrometers
application/octet-stream - 1.3 MB - MD5: 0f519e530df727468689994ecb756ba3
ThermoScientific ANTARIS II spectrometer gave absorbance spectra in wave numbers with a range of 4000 to 10001 cm-1 and a resolution of 3.86 cm-1. Samples were divided into 10 subsamples (aliquots) and poured into 0.8 cm diameter vials (about 2ml) which was scanned once. For each... |
application/vnd.oasis.opendocument.spreadsheet - 85.4 KB - MD5: 997a6b203e1a47fd62b0774a172146b2
List of the 192 primers used to amplify a 400pb fragment of 95 genes present in single copy in the Erysiphe alphitoides draft genome |
Jan 22, 2020 -
Microhaplotype genotyping-by-sequencing of 98 highly polymorphic markers in three chestnut tree species
application/gzip - 640.1 KB - MD5: f450d3a1f5ae4b1b14393a5ce78c150a
|
text/tab-separated-values - 69.8 MB - MD5: 3aac2c0b7e152639b04e171ef326632a
Liste et description des simulations réalisées avec le modèle STICS sur les sites climatiques 21 à 24 |
text/tab-separated-values - 72.5 MB - MD5: 77386d0aea06dbae6f23bc3f65dd9578
Liste et description des simulations réalisées avec le modèle STICS sur les sites climatiques 17 à 20 |
text/tab-separated-values - 52.9 MB - MD5: d08d24fa253d1dc6505000c6a7778447
Liste et description des simulations réalisées avec le modèle STICS sur les sites climatiques 13 à 16 |